Frozen coils and frozen drains
Ice shows up in two surprising places on the Front Range: on the evaporator coil of an air conditioner on a hot day, and in the condensate line of a furnace on a cold night. Different seasons, different parts, and a surprisingly similar cause.
- 1 Thermostat: It decides when everything starts. In April it can call for heat at dawn and cooling by afternoon.
- 2 Return and filter: Where the house breathes in. Dry Front Range air clogs it faster than most owners expect.
- 3 Furnace: In a basement closet, idle for six months, then asked for everything on the first cold night.
- 4 Coil and condensate drain: Ice in July if airflow drops, a frozen drain line in January if the route crosses a cold corner.
- 5 Basement ducts: Sheet metal through the joists and up old chases, with leaks in places nobody visits.
- 6 Outdoor unit: Thin air, cottonwood fluff in June and a long dry spell: less margin than the label implies.
Ice on the coil in summer
An evaporator coil gets cold, and as long as air moves across it the coil stays just above freezing. Take away the airflow with a clogged filter, a blocked return, a slow blower or a dirty coil, or take away refrigerant through a leak, and the coil temperature drops below freezing and ice forms. Dry air does not prevent it: there is enough moisture in the house to build a surprising amount of ice.
The first step when you see ice is to turn the cooling off and run the fan to let it melt, then look at the filter. If it comes back, the cause needs to be found, not cleared, because repeated freezing is hard on the compressor.
A frozen drain in winter
High-efficiency furnaces drain condensate through a small line. In a basement corner, a garage or a crawl space where the temperature drops below freezing, that water can freeze in the line, and the furnace shuts itself off to protect the system. The cure is a line that is insulated, sloped properly and routed through conditioned space where possible, sometimes with heat tape.
This is among the most common winter service calls in the metro and one of the most avoidable. A quick look at where the line runs in September saves a cold morning in January.
What to check yourself
Replace the filter, make sure the return grille is clear and check that the registers are open. Look at where the condensate line goes and whether anything has pinched it. If ice returns, or if the furnace repeatedly locks out, a technician should measure airflow and refrigerant or trace the drain.